• A-Scan Plus Connect - ultrasound probe and interface unit
  • 24-4400-24-4400V_3
  • 24-4400-24-4400V_4
  • 24-4400-24-4400V_5
  • 24-4400-24-4400V_6
  • 24-4400-24-4400V_7

A-Scan Plus Connect – ultrasound probe and interface unit

Find a distributor

High quality visuals and accurate biometric measurements, on demand

The most demanding cataract surgery requires powerful equipment and the A-Scan is the single most effective solution for measuring, calculating and refining your refractive cataract surgical outcomes. Designed to take accurate biometric measurements, the A-Scan probe can be used to measure ocular axial length in contact or immersion modes and it is particularly useful for patients or animals with fixation difficulties or dense cataracts.

Working in harmony with Keeler Connect software (which can be plugged into any Windows™ laptop or desktop computer), A-Scan Plus Connect is intuitively designed and fully portable, making it the perfect companion for busy eye imaging professionals, either in clinic or on-the-go

The A-Scan probe is also fully compatible with the Keeler 4Sight™ ultrasound system – our all-in-one ultrasound solution.

Benefits:

  • Improved visuals
  • Easy to use interface with time-saving functionality
  • Wavelength spike patterns for accurate and precise measurements
  • Includes six IOL formulas
  • Includes four post-refractive formulas
  • Competitive warranty and great customer support

Accessories included: power adaptor, footswitch, software installation, test block, and immersion shell

SKU: 24-4400/24-4400V Category:

High quality visuals

Featuring optimised lens constants for improved visuals, the A-scan probe allows you to see visuals that would otherwise be obscured by cataracts or vitreous haemorrhages, providing superior surgical outcomes for your patients.

Easy to use interface

The smooth interface makes the A-scan probe easy to use, and allows you to create default settings that you can go back to again and again without interruptions. The system also automatically creates electronic medical records for your patients, giving you peace of mind for future examinations.

Wavelength spike patterns

Working on 10 MHz broadband, the A-Scan probe can be used to measure ocular axial length in both contact or immersion modes. Each measurement with the A-scan captures up to 5 wavelength spike patterns, using independent velocities for each portion of the eye, as well as the average and standard deviation of each anatomical measurement to give you the most accurate results.

IOL formulas

Includes 6 IOL formulas: Hoffer Q, SRK/T, Holladay I, Haigis, SRK II, Binkhorst II.

Post refractive formulas

The A-scan also has post refractive measurement capabilities, using 4 formulae: Contact Lens, Entered, Clinical History and Shammas Clinical.

Great value

At Keeler, we believe that value is more than the price alone. We look at every detail and quality components, results and high build quality shouldn’t cost the earth.

Support when you need it

True partnerships don’t stop, our industry-leading warranty and service programs, as well as our live help facility offer dependable support for the life of the product.

Features – Keeler Connect software:

  • Intuitive interface
  • Industry leading portability
  • Ultrasound compatibility
  • Great value
  • Competitive warranty and great customer support
  • Features – A-Scan probe:

    • Immersion and contact modes
    • Customizable lens, ACD and VCD materials for new emerging implant/chamber materials
    • Optimized lens constants for superior surgical outcomes
    • Easy to set up defaults, smooth customer interface and automatic EMR exports to decrease examination time, increase patient throughput, and increase profit
    • Automatic alignment detection and sclera recognition help eliminate marginally aligned scans
    • Seamless work flow integration with IOLMaster 500 from ZEISS
    • Fully upgradeable software
    • Unlimited data storage based on PC/network storage
    • EMR capability with automatic transfer of data
    • DICOM ready
    • Unlimited IOL Lens groups
    • Piggyback calculation ability for ICL implant patients
    • Rx surgery calculations for an aging Lasik population
    • PC based platform
    • PDF reporting

    Specification:

    • Capture Modes: Automatic or manual
    • Clinical accuracy: 0.1mm
    • Custom eye type settings: Unlimited with independent ACD, Lens, VCD velocities.
    • Data export: EMR/EHR compatible, Network ready
    • Default eye type settings: Phakic, Dense Cataract, Silicone Filled, Pseudo PMMA, Pseudo Silicone, Pseudo Acrylic, Aphakic
    • Dimensions: 5.4″W x 3.7″L x 2.5″H
    • Electronic resolution: 0.016mm
    • Frequency: 10MHz
    • Gain: 30-100dB
    • IOL Data Storage: Unlimited
    • Measurement range: 0.01-63.6mm
    • Measurements: ACD, Lens thickness, VCD, Axial Length
    • Methods: Immersion or contact
    • Patient data storage: Unlimited
    • Post refractive formula methods: Clinical history, Contact lens, Shammas clinical
    • Printer: Any supported by PC
    • Weight: 15.1 oz

For all documentation associated with this product including cleaning instructions, product support and instruction manuals, please visit our support page here